Linker script injection via split -Wl, flags and Darwin or symbol linker flags in cgo in cmd/go

Published 11 Nov 2026 · Source updated 17 Nov 2026 · Retrieved 2026-11-19 04:34 UTC

Monitor this CVE ↗Full CVE monitoring on Pro and Business

What happened?

Building a malicious package that uses cgo could cause arbitrary code execution at link time by passing linker script files to the host linker via "#cgo LDFLAGS". Split "-Wl," flags that consume a following argument (such as "-Wl,-rpath", "-Wl,--just-symbols", and "-Wl,-undefined") previously accepted a bare second argument without a "-Wl," prefix, which the compiler driver passes directly to the linker as a positional input file. Additionally, when using GNU ld.bfd, flags such as "-framework", "-Wl,-framework", "-Wl,-undefined", "-Wl,--just-symbols", "-Wl,-R", "-Wl,-subsystem", and (on non-Darwin platforms) "-Wl,-sectcreate" could cause ld.bfd to interpret their arguments as linker scripts if they named a regular file on disk. The go command now requires a "-Wl," prefix on the second token of split "-Wl," flags (except "-Wl,-R"), verifies that these flags do not reference linker script files, and disallows bare "-Wl,--warn-backrefs-exclude".

Description supplied by CVE Program. Formatting is simplified; follow the original advisory for full details.

Affected software and versions

Source-provided software and version information
SoftwareVersion informationFixed version
cmd/goGo toolchainaffected: 0 to < 1.26.11; affected: 1.27.0-0 to < 1.27.4See vendor advisory

Version information comes from the source record and can include unaffected products and exceptions. Distribution packages may contain backported fixes: an older upstream version alone does not prove a server is affected.

Is it being exploited?

This CVE was not listed in the CISA catalogue at our last retrieval. This does not establish that exploitation is absent.

CISA data retrieved 2026-11-19 21:16 UTC. Check CISA ↗

How to respond

  1. Confirm the product, installed package version, and any configuration requirements in the vendor advisory.
  2. Follow the vendor’s remediation or workaround guidance in the references below. Structured fixed-version data is unavailable here; the publisher’s description may include a fix or workaround.
  3. Restart affected services if required, then verify the running version. Known exploitation may warrant investigation as well as patching.

Sources and remediation references

This public advisory does not determine whether a particular server is affected. Records are refreshed as sources change; verify urgent decisions against the original advisory.

← Browse the public CVE feed